To know more about EMT conduits below are a few common questions answered by Experts. And yes it can be buried.
While NM cable can be run inside conduit this is seldom done.

Can Emt Conduit Be Used Inside Kitchen Cabinet. Says so in 35810B B Corrosion Protection. Article 320 is for AC 330 is for MC and 334 is NM. It would have to stick out inside the cabinets.
The box can be mounted above the fixture and a metal nipple can be installed between the fixture and the metal junction box. It is the lightest and thinnest of the rigid metal conduit types and comes in a few different diameters. Rewiring a House From the Outside Using Conduit.
Outdoor flexible nonmetallic tubing is strong watertight non-corrosive and weighs less. Old wiring can present a fire hazard but is extremely expensive and complicated to replace. The electrical wiring inside the cabinet should be protected by installing it into flex conduit.
If possible I try to be there when the cabinets are installed run underneath by boring thru any joiner wood and come straight up as far back as possible with emt or flex into a metal work box. Its easy now for some like yourself to go online and google these Articles. There is usually a corner back of the drawers with enough clearance even if you need a 90 bend.
Even though EMT is made of lighter-walled steel it still provides substantial physical protection and can be used in most exposed locations except where severe physical damage is a possibility. Rather than tear out walls or spend weeks fishing. The EMT conduit can be used as a grounding conductor which includes the set screw or the compression connectors and couplings.
The answer to your question is NO. Some code-compliant PVC fittings can be used with ENT inside walls floors some ceilings or encased in concrete. I know that the electrical wire cannot be bent much but we were allowed to use short 90 degree elbows like the one linked below I was not able to find them anywhere in US.
PVC coatings may be used over bare or galvanized steel conduit or conduit that has a supplementary zinc coating. How to Install Electrical Wiring for Kitchen Cabinet Light Fixtures. 12-inch is the most standard size for household circuits.
This can be found in Chapter 3 of the NEC. This differs from cable which is a group of wires encased inside a flexible protective sheathing. Up to 12 of the 14-gauge wires.
Up to 9 of the 12-gauge wires. Metal or plastic boxes can be used with nonmetallic conduit. The flex conduit can be run to a metal junction box such as a handy box or single gang box.
IMC has a thinner wall and weighs less than RMC. Technically youre not allowed to make joints in a panel enclosure with the hot or neutralsOr land two wires on a breakerTo follow the letter of the code you could intercept the conduit run before the paneland relocate the recptacle thats fed with romex thereOne hot and neutral per circuit into the panel. Conduit is a hollow tube that wires are pulled or fished through during installation.
Unless otherwise provided cables shall be secured at intervals not exceeding 18 m 6 ft. There shouldnt be conventional romex in conduit underin that concrete slab either. EMT is the lightest-weight steel conduit manufactured.
What kind of wiring can be used in a kitchen island. Up to 22 of the 14-gauge wires. Cables containing four or fewer conductors sized no larger than 10 AWG shall be secured within 300 mm 12 in of every box cabinet fitting or other cable termination.
Additionally there may not be a need for equipment ground in an EMT conduit. 12-1402 Use 1 Electrical metallic tubing shall be permitted to be used for exposed and concealed work except that it shall not be used d in wet locations. The National Electrical Code has specific regulations for how many conductor wires can fit within a conduit of each diameter size.
And 12-1410 Connections and couplings Where lengths of electrical metallic tubing are coupled together or connected to boxes fittings or cabinets fittings shall be. Electrical metallic tubing or EMT is the most common type of conduit for exposed interior installations such as in a basement or an unfinished garage or workshop. It can be used indoors outdoors underground and in both concealed and exposed applications.
The most common type of cable used in home wiring is non-metallic NM or Romex cable. Curious as to why you consider NM run along the upper backside inside of a kitchen island subject to physical damage. Blue electrical nonmetal tubing ENT is for indoor use only.
However it is advisable to have one present. Up to 16 of the 12-gauge wires. IMC can be used for the same applications as galvanized RMC.
Ferrous or nonferrous EMT elbows couplings and fittings shall be permitted to be in-stalled in concrete in direct contact with the earth or in areas subject to severe corrosive influences where protected. Each article lists the uses permitted and uses not permitted. Even in the back of a cabinet the romex is subject to physical damage and must be protected conduit.
Halex 1 2 In 2 Hole Electrical Metallic Tube Emt Straps 4 Pack 96161 The Home Depot Metal Electrical Box Zinc Plating Wooden Yard Decorations
1808 W Indianola Avenue Conduit Lighting Pvc Conduit Exposed Conduit
Building A Kitchen Island Running Electrical Conduit Diy Home Improvement Forum
1 2 Inch Electrical Conduit Emt Makes A Great Frame For A Trellis Outdoor Gardens Dream Garden Vertical Garden
Turquoise Electrical Conduit Is A Design Feature Running Through This Office Space Office Interior Design Interior Design Inspiration Electrical Conduit
Remodelista Sourcebook For The Considered Home Trending Decor Copper Kitchen Sweet Home
Installing Surface Mounted Wiring Home Electrical Wiring Electrical Wiring Electricity
Cabinet Door On Drying Racks Painting Drying Rack Art Studio Room Art Studio Storage
Door Rack Painter Review A Cabinet Drying Rack For Pros Door Rack Painting Kitchen Cabinets Repainting Cabinets
Allied 583195 14 99 Emt Conduit 1 2 In 10 Ft L Steel Steel Galvanized Steel Emt
Receptacles In An Unfinished Basement Unfinished Basement Basement Exposed Electrical
Conduit In Basement Google Search Surface Mounted Wiring Electrical Wiring Metal Electrical Box
Great Traditional Kitchen In Thomasville Nc Traditional Kitchen Paint Traditional Kitchen Kitchen
Tiny Apartments Plans 10 Clever And Ingenious Ways To Deal With The Lack Of Space Apartment Interior Design Tiny Apartments Apartment Interior
Emt Conduit In Copper Paint On Exposed Ceiling Electrical Projects Electrical Wiring Electrical Installation
Building A Kitchen Island Running Electrical Conduit Diy Home Improvement Forum